Web-Select Help & Info |
Belt Drive Blower Coil
Unit Options
Unit Options is part of the BCU Pricing Screen. Available choices are
based on the selected model and coil. Click the appropriate link below
for details on that model and coil combination:
To clear all selections and return all fields to their defaults, click the
brower's Refresh button.
See Also:
BCU Coils
BCU Unit Information
BCU Table of Contents
Unit Options for Horizontal and Vertical Belt Drive
BCU.
- Base Rails: Check the box to select.
- Foil Options: Check the box to select.
- Access Door: Choose an access door style, or leave the default at
None.
- Filter Rack: Choose from the drop-down menu. The default is None.
- Filter Type: Choose from the available options. The default is 2"
Throwaway.
- Spare Filter: Select a spare filter, or leave the default at
None. Multiple filters may be ordered by entering the desired number
in the Spare Filter Qty. box.
- Drain Pan: Select the drain pan construction type.
- Disconnect Switch: Choose a style of disconnect switch. The default
is none.
- Conduit: Check the box to select.
- Main Fusing: Choose a main fusing. The default is none.
- Fusing Per Step: Choose from the drop-down menu. The default is None.
- Hand-Off Auto (HOA) Switch: Check the box to select.
- Fan Control Package: Choose from the drop-down menu. The default
is None. A fan control package is required on units with electric heat.
- Motor HP: The program automatically selects the appropriate horsepower,
based on the airflow and total static pressure from the unit selection. A
higher horsepower may be selected (WARNING: Selecting a larger horsepower
than required will result in increased amp draw, which may effect fuse and
disconnect sizing. See catalog for more information).
- Motor Handing: The default at Right Hand. Choose Left Hand if desired.
- Spare Belts: Select a spare belt, or leave the default at None. Multiple
belts may be ordered by entering the desired number in the Spare Belt Qty.
box.
- SFA Number: If you have a Special Feature Authorization (SFA), include
the SFA Number and dollar amount in the fields provided.
Unit Options for Vertical Reduced Footprint Belt Drive BCU - Rear and Bottom Return.
- Base Rails: Check the box to select.
- Access Door: Choose an access door style, or leave the default at
None.
- Filter Rack: Choose from the drop-down menu. The default is None.
- Filter Type: Choose from the available options. The default is 2"
Throwaway.
- Spare Filter: Select a spare filter, or leave the default at
None. Multiple filters may be ordered by entering the desired number
in the Spare Filter Qty. box.
- Drain Pan: Select the drain pan construction type.
- Disconnect Switch: Choose a style of disconnect switch. The default
is none.
- Conduit: Check the box to select.
- Main Fusing: Choose a main fusing. The default is none.
- Fusing Per Step: Choose from the drop-down menu. The default is None.
- Hand-Off Auto (HOA) Switch: Check the box to select.
- Fan Control Package: Choose from the drop-down menu. The default
is None. A fan control package is required on units with electric heat.
- Motor HP: The program automatically selects the appropriate horsepower,
based on the airflow and total static pressure from the unit selection. A
higher horsepower may be selected (WARNING: Selecting a larger horsepower
than required will result in increased amp draw, which may effect fuse and
disconnect sizing. See catalog for more information).
- Motor Handing: The default at Right Hand. Choose Left Hand if desired.
- Spare Belts: Select a spare belt, or leave the default at None. Multiple
belts may be ordered by entering the desired number in the Spare Belt Qty.
box.
- SFA Number: If you have a Special Feature Authorization (SFA), include
the SFA Number and dollar amount in the fields provided.